| SGR Master Condition Rating Definitions for RTD | 
| This rating is based on how close an asset or component is to replacement or major overhaul.  Scores will not have a greater granularity than a half point.  An asset is in a State of Good Repair if the score is greater than (2.5).  Refer to individual asset group Inspection Standards Document for confidence in reliability and specific examples. Confidence in Reliability = Remaining Useful Life  | 
| 5.0) New or like new, 95% to 100% confidence in reliability; no visible defects, no damage, cosmetically looks new. An asset is only new once, after rebuild some old parts are not new and therefore the highest score after rebuild is (4.5). | 
| 4.5) The inspector is 90% to 95% confident in the reliability of the component / asset. | 
| 4.0) The inspector is 80% to 90% confident in the reliability of the component / asset. Shows minimal signs of wear, no major defects, and some minor defects with only minimal signs of deterioration. Cosmetic defects/minor wear.  | 
| 3.5) The inspector is 70% to 80% confident in the reliability of the component / asset. | 
| 3.0) The inspector is 60% to 70% confident in the reliability of the component / asset. Some moderately defective or deteriorated components; expected maintenance needs.  Cosmetically “fair” but all devices are functioning as designed. Small repairs or minor refurbishment.  | 
| 2.5) The inspector is 50% to 60% confident in the reliability of the component / asset. | 
| 2.0) The inspector is 40% to 50% confident in the reliability of the component / asset. Asset near overhaul or retirement, but in serviceable condition. Asset has increasing number of defects or deteriorated component(s). Significant or multiple repairs needed.  | 
| 1.5) The inspector is 30% to 40% confident in the reliability of the component / asset. | 
| 1.0) The inspector is less than 30% confident in the reliability of the component / asset. Asset is in need of major repair or refurbishment, multiple minor defects or major defects.  Evidence of corrosion may be apparent; major or numerous minor areas of damage or structural issues. Safety concern, critical damage, close to or time for overhaul or replacement.  | 
| 0) Not safe to use, multiple major repairs or Asset set for disposal/retirement. | 
To view the entire Facilities Procedures handbook for RTD return to the main page and filter the library to “Full Policy Handbooks.”
